servejae.blogg.se

Silent knight 5700 default installer code
Silent knight 5700 default installer code




  1. #Silent knight 5700 default installer code install#
  2. #Silent knight 5700 default installer code manual#
  3. #Silent knight 5700 default installer code software#

The 6700 also has Form C trouble relay, and two programmable Form C relays, along with powerful features such as drift compensation, pre-trouble maintenance alert, a built-in sensor test to comply with NFPA 72 calibration testing requirements, and calibration trouble alert. It is not compatible with Hochiki (SD) devices.

silent knight 5700 default installer code

#Silent knight 5700 default installer code manual#

SWIFT is only compatible with System Sensor (SK) devices. SilentKnight SK-5700 User Manual 7.6.6.1 Automatic Daylight Savings Adjustment 7.6.6.2 Daylight Saving Time Start and End 7.6.7 Edit Banner 7.6.8 SLC Family 7.7 JumpStart Autoprogramming 7.8 Computer Account 7.9 Access Codes 7.9.1 Profile Edit Menu 7.9.1.1 Edit Name 7.9.1.2 Edit Access Code 7.9.1.3 Panel Functions 8. Combine SWIFT devices with other hard-wired 6700 compatible devices.

#Silent knight 5700 default installer code install#

It is ideal for hard to-wire locations, buildings that don’t allow new wiring, or to provide an easy install fire system for new construction projects. SWIFT wireless compatibility provides options for wireless detection through a Class A mesh network. Model SK-5208 Fire Control/Communicator Installation and. The 6700 system can be enhanced by adding modules such as the 6860 remote annunciator which also has four programmable function buttons to help automate tasks and reduce time spent at the panel. If ID code 2 is selected the SK-5217 will input zones 21 - 30. Disconnect all sources of power before servicing. Operation Task to Perform Silence Alarms and Troubles Press then enter a code if prompted. Test the system in accordance to NFPA 72. It also has a built-in, dual line POTs and IP communicator and optional cellular side-cars. Installation Procedure Installation Precautions - Adherence to the following will aid in problem-free installation with long-term reliability: WARNING - Several different sources of power can be connected to the fire alarm control panel. These Instructions must be framed and displayed next to the 5700 panel in accordance with NFPA 72 fire code for Local Protected Fire Alarm Systems.

#Silent knight 5700 default installer code software#

A designated panel is configured as the communicator for all panels in the link for convenient single-point communications. SKSS Software 5660 and Manual 151240 Rev: H 151240:H ECN: 16-0073 KEY: mcLd2z3628863345 Key is not case sensitive should not be any spaces in-between. A common communications and annunciation link allows connection of up to 17 panels via copper or fiber optic cable. It has one built-in signaling line circuit (SLC), which can support 50 System Sensor (SK) sensors and 50 SK modules or 50 Hochiki (SD) devices per loop.

silent knight 5700 default installer code

The 6700 is an addressable fire alarm control panel (FACP) that can be configured to achieve an overall point capacity of up to 100 points. Description Silent Knight 6700 100-Point Single Loop Addressable Fire Alarm Control Panel (Replaces 5700)






Silent knight 5700 default installer code